97
# Verify that the user cannot ping the FTP server at any time from 8:00 to 18:00 on any weekday.
C:\>ping 10.0.0.1
Pinging 10.0.0.1 with 32 bytes of data:
Request timed out.
Request timed out.
Request timed out.
Request timed out.
Ping statistics for 10.0.0.1:
Packets: Sent = 4, Received = 0, Lost = 4 (100% loss),
The output shows that ACL 3000 is active on the user, and the user cannot access the FTP server.
802.1X with EAD assistant configuration example
Network requirements
As shown in Figure 33:
• The intranet 192.168.1.0/24 is attached to Ten-GigabitEthernet 1/0/1 of the access device
.
• The hosts use DHCP to obtain IP addresses.
• A DHCP server and a Web server are deployed on the 192.168.2.0/24 subnet for users to obtain
IP addresses and download client software.
Deploy an EAD solution for the intranet to meet the following requirements:
• Allow unauthenticated users and users who have failed 802.1X authentication to access
192.168.2.0/24. The users can obtain IP addresses and download software.
• If these users use a Web browser to access a network other than 192.168.2.0/24, redirect them to
the Web server for 802.1X client downloading
.
• A
llow authenticated 802.1X users to access the network.

Table of Contents

Other manuals for HP FlexFabric 5700 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP FlexFabric 5700 series and is the answer not in the manual?

HP FlexFabric 5700 series Specifications

General IconGeneral
BrandHP
ModelFlexFabric 5700 series
CategorySwitch
LanguageEnglish

Related product manuals