14 ELECTRICAL SYSTEM 88
Recharge the battery.
Guideline
The charging current, charging voltage, and charging time must not be
exceeded.
Maximum charging voltage 14.4 V
Maximum charging current 3.0 A
Charge the battery regularly when
the motorcycle is not in use
6 months
Info
Never remove cover
.
Connect the battery charger to the battery. Switch on the battery charger.
Battery charger (81229074000)
In addition, this battery charger can be used to test the quiescent current, the
start ability of the battery, and the alternator. With this device, you cannot over-
charge the battery. The charging time may be longer at low temperatures.
Switch off the battery charger after charging and disconnect from the battery.
Finishing work
Install the battery. ( p. 86)
Mount the seat. ( p. 54)
Install the air filter box cover. ( p. 56)
14.4 Changing the main fuse (TX 300)
Warning
Fire hazardIncorrect fuses overload the electrical system.
Only use fuses with the required ampere value.
Do not bypass or repair fuses.
Info
The main fuse protects all power consumers of the vehicle. It is located in the starter relay housing under the seat.
Preparatory work
Switch off all power consumers and switch off the engine.
Remove the air filter box cover. ( p. 55)
Remove the seat. ( p. 53)
E00308-10
Main work
Pull starter relay
from the holder.