7--4
87
Use and maintenance manual S20DSP
ifthevaluesissetas0,thebladestopsintheFCTA(forwardheadlimit
switch) point.
NEVER/FCTI/FCTA: 0
BLADE MOTOR OFF
Cutting vice opening setting
" Press the " key to display the parameter indicating if the shearing vice must
open when the head is in the FCTI (backward head limit switch) point or in
the FCTA (forward head limit switch) point; press Y to set the val ue as 0
(vice opening in FCTA), or as 1 (vice opening in FCTI).
FCTA/FCTI: 1
CUTTING VICE OPENING
Cutting vice opening/closing time setting
" Press the " key to display the parameter indicating the time between the vice
closing and the cut start and between the cut end and the vice re---opening.
Press Y to change this value, ranging between 0.0 and 9.9 seconds.
TIME = 0.0
VICE OPENING/CLOSING
Machine maximum power input setting
" Press the " key to display the parameter and then increase or reduce the
value with the Y key.
BLADE = 00.0
MOTOR I MAX
The factory set values are relative to the motor installed on the machine.
Measurement unit setting
" Press the " key to display the parameter, then press Y to set the value as 0
or 1, to choose the measurement unit expressed respectively in pounds or
kilograms .
FIPS/MKS = 0
MEASUREMENT UNIT
N.B.