Table 15. Location requirements (continued)
Criteria Deîš³nition
Air quality
• Place the library in an area with minimal sources of particulate
contamination.
• Avoid areas near frequently used doors and walkways, stacks of supplies
that collect dust, printers, and smoke-îš³lled rooms.
• Excessive dust and debris can damage tapes and tape drive.
Technical speciîš³cations for this library can be referenced in the following tables.
Physical speciîš³cations
Table 16. Physical speciîš³cations
Characteristic Product alone Packaged
Height 133 mm 330 mm
Width 480 mm
1
635 mm
Depth 885 mm
2
1168 mm
Weight
Base module: 20 Kg
Expansion module: 13 Kg
Base module: 25 Kg
Expansion module: 19 Kg
1
Includes front covering of rack rails, allowing for magazine opening clearance.
2
From the front of the bezel to the back of the fan on an inserted drive sled.
Electrical speciîš³cations for one module (base or expansion)
Table 17. Electrical
speciîš³cations for one module (base or expansion)
Characteristic Speciîš³cation
Current max. 12.5 A
Voltage 100 - 240 V 50/60 Hz
Power 300 W
24 IBM TS4300 Tape Library Machine Type 3555: User's Guide