65
11
CONTROL COMMAND
New2001
Cmd.
Sub
Cmd.
Data Description
00 see the right Send frequency data for transceive
01 02, 05, 06 Send mode data for transceive
02=AM, 05=FM, 06=WFM
03 see the right Read operating frequency
04 02, 05, 06 Read operating mode
02=AM, 05=FM, 06=WFM
05 see the right Set operating frequency
06 02, 05, 06 Operating mode selection
02=AM, 05=FM, 06=WFM
11 00/10 Send/read the attenuator function
setting
00=OFF, 10=ON (approx. 10dB)
12 00/01 Send/read ANT selection
0.495 to 1.620 MHz band:
00=EXT, 01=BAR*
*“BAR” can only be selected in AM mode.
Other frequency band:
00=EXT, 01=EAR
14 01 see p. 66 Send/read the volume level
03 see p. 66 Send/read the squelch level
15 01 00/01 Read the squelch status
00=Squelch close, 01=Squelch open
02 see p.66 Read the S-meter level
16 43 00, 01, 02 Send/read the tone squelch setting
00=OFF, 01=TSQL, 02=TSQL-R
4B 00, 01, 02 Send/read the DTCS squelch setting
00=OFF, 01=DTCS, 02=DTCS-R
Cmd.
Sub
Cmd.
Data Description
16 4C 00/01 Send/read the VSC function setting
00=OFF, 01=ON
19 00 Read the receiver ID
1A 00 00/01 Send/read the AF filter setting
00=Filter OFF, 01=Filter ON
1B 01 see p. 66 Set/read TSQL tone frequency
02 see p. 66 Set/read DTCS code with polality
D Data content description
• Receive frequency (Command: 00, 03, 05)