Figure 2-7 Mounting dimensions of the CS500
95.00
99.30
2.5.4 Mounting Dimensions of the External DC Reactor
Figure 2-8 Mounting dimensions of the external DC reactor
Table 2-4 Adapted DC reactor and mounting dimensions
Adaptable AC Drive Model A B C D E F G
Fixed
Hole
Diameter of
the Hole for
Connecting
the Copper
Busbar
Reactor
Model
CS500-4T75G/90G 160 190 125 161 192 255 195 10*15 Ø12 DCL-0200
CS500-4T110G 160 190 125 161 192 255 195 10*15 Ø12 DCL-0250
CS500-4T132G/160G/185G 160 190 125 161 192 255 195 10*15 Ø12 DCL-0360
CS500-4T200G/220G 190 230 93 128 250 325 200 13*18 Ø15 DCL-0600
CS500-4T250G/280G 190 230 93 128 250 325 200 13*18 Ø15 DCL-0700
CS500-4T315G/355G/400G 224 250 135 165 260 335 235 12*20 Ø14 DCL-1000
Customized models can be provided for special requirements.