Environmental Limits Specification Intel® Server Board S1200V3RP TPS
Revision 1.2
the responsibility of the system integrator who chooses not to use Intel developed server
building blocks to consult vendor datasheets and operating parameters to determine the amount
of airflow required for their specific application and environmental conditions. Intel Corporation
cannot be held responsible, if components fail or the server board does not operate correctly
when used outside any of their published operating or non-operating limits.
12.2 MTBF
The following is the calculated Mean Time Between Failures (MTBF) 40 degree C (ambient air).
These values are derived using a historical failure rate and multiplied by factors for application,
electrical and/or thermal stress and for device maturity. You should view MTBF estimates as
“reference numbers” only.
Calculate standard: Telcordia* issue 2
Calculate Method: Method I-D
Temperature = 40 degree C
Environment = GB, GC – Ground Benign, Controlled
Model = Serial
Duty cycle = 100%
Component Quality: Level II
Adhere to De-rating data
Table 62. MTBF Estimate
Intel
®
Server Board
S1200V3RPL
Intel
®
Server Board
S1200V3RPS
Intel
®
Server Board
S1200V3RPO
Intel
®
Server Board
S1200V3RPM