EasyManuals Logo
Home>Intel>Server Board>S1200V3RP

Intel S1200V3RP Technical Product Specification

Intel S1200V3RP
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Intel® Server Board S1200V3RP TPS Functional Architecture
Revision 1.2
19
- Gen3 speeds at 8 GT/s (no 8b/10b encoding)
- Can operate at 2.5 GT/s, 5 GT/s, or 8 GT/s
The Intel
®
Server Board S1200V3RPL and S1200V3RPS support PCIe slots:
- Slot 7: PCI Express* Gen2 x1 electrical with x8 physical connector, from PCH.
- Slot 6: PCI Express* Gen2 x 16 or Gen3 x8 electrical with x16 physical connector,
from processor.
- Slot 5: PCI Express* Gen2 x8 or x4 electrical with x8 physical connector, from
processor.
- Slot 4: PCI Express* Gen2 x4 electrical with x8 physical connector, from PCH.
The Intel
®
Server Board S1200V3RPO and S1200V3RPM support PCIe slots:
- Slot 6: PCI Express* Gen3 x16 electrical with x16 physical connector, from processor.
Table 5. PCI Express* Speed Matrix for Each Configuration
Board Name
PCI Express* Slot
S1200V3RPS
Slot4
Slot7
Slot5
Slot6
PCI
Express*
Gen2 x4
PCI
Express*
Gen2 x1
PCI Express* Gen2
x8
PCI
Express*
Gen3 x8
S1200V3RPL
Slot4
Slot7
Slot5
Slot6
SAS Module
PCI
Express*
Gen2 x4
PCI
Express*
Gen2 x1
No card
installed
PCI
Express*
Gen3 x8
or Gen2
x16
No Card
installed
PCI
Express*
Gen3 x8
PCI
Express*
Gen2 x8
PCI
Express*
Gen2 x8
PCI
Express*
Gen3 x8
No Card
installed
PCI
Express*
Gen2 x4
Gen3 x8
PCI
Express*
Gen2 x4
S1200V3RPO
S1200V3RPM
Slot6
IO Module
SAS module
PCI
Express*
Gen2 x16 or
Gen3 x8
Don’t have add-in
module
Don’t have add-in module
PCI
Express*
Gen3 x8 or
don’t have
add-in card
PCI Express* Gen2 x8
Don’t have add-in module
Don’t have add-in
module
PCI Express* Gen2 x4
PCI Express* Gen2 x4
PCI Express* Gen2 x4
Note: If no device is installed on IO Module connector or Slot5, the device connecting to Intel
®
SAS module connector can work as PCI Express* Gen2 x4 electrical; if any device is installed
on IO Module connector or Slot5, the Intel
®
SAS modules (RMS25JB080 and RMS25JB040)
can work as PCI Express* Gen2 x4 electrical and the Intel
®
ROC modules (RMS25CB080 and
RMS25CB040) cannot be detected.

Table of Contents

Other manuals for Intel S1200V3RP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S1200V3RP and is the answer not in the manual?

Intel S1200V3RP Specifications

General IconGeneral
BrandIntel
ModelS1200V3RP
CategoryServer Board
LanguageEnglish

Related product manuals