Intel® Server Board S1200V3RP TPS Platform Management Functional Overview
Revision 1.2
45
Feature
Basic*
Advanced**
Diagnostic Beep Code Support
Yes
Yes
Power State Retention
Yes
Yes
ARP/DHCP Support
Yes
Yes
PECI Thermal Management Support
Yes
Yes
E-mail Alerting
Yes
Yes
Embedded Web Server
Yes
Yes
SSH Support
Yes
Yes
Integrated KVM
Yes
Integrated Remote Media Redirection
Yes
Lightweight Directory Access Protocol (LDAP)
Yes
Yes
Intel
®
Intelligent Power Node Manager
Support***
Yes
Yes
SMASH CLP
Yes
Yes
* Basic management features provided by Integrated BMC
**Advanced management features available with optional Intel
®
Remote Management Module 4
*** Intel
®
Intelligent Power Node Manager Support requires PMBus*-compliant power supply
6.3 Advanced Configuration and Power Interface (ACPI)
The server board supports the following ACPI states.
Table 16. ACPI Power States
State
Supported
Description
S0
Yes
Working.
The front panel power LED is on (not controlled by the BMC).
The fans spin at the normal speed, as determined by sensor inputs.
Front panel buttons work normally.
S1
Yes
Sleeping. Hardware context is maintained; equates to processor and chipset clocks
being stopped.
The front panel power LED blinks at a rate of 1 Hz with a 50% duty cycle (not
controlled by the BMC).
The watchdog timer is stopped.
The power, reset, front panel NMI, and ID buttons are unprotected.
Fan speed control is determined by available SDRs. Fans may be set to a fixed
state, or basic fan management can be applied.
The BMC detects that the system has exited the ACPI S1 sleep state when the BIOS
SMI handler notifies it.
S2
No
Not supported.
S3
No
Supported only on Workstation platforms. See appropriate Platform Specific Information
for more information.
S4
No
Not supported.
S5
Yes
Soft off.
The front panel buttons are not locked.
The fans are stopped.
The power-up process goes through the normal boot process.
The power, reset, front panel NMI, and ID buttons are unlocked.

Table of Contents

Other manuals for Intel S1200V3RP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S1200V3RP and is the answer not in the manual?

Intel S1200V3RP Specifications

General IconGeneral
BrandIntel
ModelS1200V3RP
CategoryServer Board
LanguageEnglish

Related product manuals