Intel® Server Board S1200V3RP TPS Platform Management Functional Overview
Revision 1.2
6.11.15.3 Output Data Categories
The following tables list the data to be provided in the diagnostic output.
Table 21. Diagnostic Data
Human-readable SEL listing
Human-readable sensor listing
BIOS configuration settings
POST codes for the two most
recent boots
SMBIOS table for the current
boot
256 bytes of PCI config data for
each PCI device
Memory Map (EFI and Legacy)
for current boot
Table 22. Additional Diagnostics on Error
First 256 bytes of PCI config data
for each PCI device
6.11.16 Data Center Management Interface (DCMI)
The DCMI Specification is an emerging standard that is targeted to provide a simplified
management interface for Internet Portal Data Center (IPDC) customers. It is expected to
become a requirement for server platforms which are targeted for IPDCs. DCMI is an IPMI-
based standard that builds upon a set of required IPMI standard commands by adding a set of
DCMI-specific IPMI OEM commands. Intel
®
S1400/S1600/S2400/S2600 Server Platforms
implement the mandatory DCMI features in the BMC firmware (DCMI 1.1 Errata 1 compliance).
Refer to DCMI 1.1 errata 1 spec for details. Only mandatory commands are supported. No
support for optional DCMI commands. Optional power management and SEL roll over feature is
not supported. DCMI Asset tag is independent of baseboard FRU asset Tag. Refer to table
DCMI Group Extension Commands for more details on DCMI commands.