Inspection and Installation
Copyright ©ITECH Electronic Co., Ltd. 33
NOTE
When the output voltage has DC voltage, the output terminal A is positive, and N is
negative.
1. Confirm that the power switch is in the OFF position and verify that there is
no dangerous voltage on the connection terminals.
2. Remove the output terminals cover of the power system.
3. Refer to the wiring diagram and connect the Vs+ and Vs- with armored
twisted-pair cables. Loosen the screws of the output terminals and connect
the red and black test cables to the output terminals. Re-tighten the screws.
When maximum current that one test cable can withstand fails to meet the
rated current, use multiple pieces of red and black test cables. For example,
the maximum current is 1,200A, then 4 pieces of 360A red and black cables
are required.
4. Thread the red and black test cables through the output terminals cover of
the power system and install the cover.
5. (Optional) According to the actual situation of DUT, connect the grounding
terminal on the rear panel of the instrument to the DUT to ensure the safe
grounding.
For the location information, see 1.5 Rear Panel Introduction.
6. Connect the other end of the remote sense cables to the DUT.
7. Connect the other end of the red and black cables to the DUT. The positive
and negative poles must be properly connected and fastened when wiring.
8. Power on the instrument and turn on the Sense function of the instrument.
2.6 Installing Fiber Cables (Only for IT7830-350-180)
IT7830-350-180 model is composed of two 15kVA parallel machines. In order to
avoid damage to the fiber cords connected in parallel with the master and slave
during transportation, the fiber cords are not installed before delivery. After
receiving the instrument, users need to install the yellow fiber cable by
themselves.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7800 Series and is the answer not in the manual?

ITech IT7800 Series Specifications

General IconGeneral
BrandITech
ModelIT7800 Series
CategoryAC Power Distribution
LanguageEnglish

Related product manuals