Motor Learn
Next, the complete motor data must be learned with the automated learn
function.
The motor characteristics, including the motors inductance and resistance,
can be learned with the drives tuning function. The Motor Learn function
can be found under the Tune Parameters group from the Programming menu
(Home > Prog > Tune Parameters > LL01). Begin the procedure by setting:
Motor Tuning LL01 = Start
Note: It may be necessary to program the drive outputs accordingly for
proper operation with the controller. Refer to Section 6.13 for setting
the output functions.
Follow the instructions on the LCD screen. The user is instructed to:
1. Disable the brake.
2. If the speed is generated by the controller (Analog or Serial), then set
external speed command to zero.
3. Press and hold inspection (speed + direction + enable inputs) until
completed. Upon successful completion LED 1 and LED 2 will blink green
and red until inspection is dropped.
The process should take 2-5 minutes and will emit a high pitched noise while
the drive measures various motor parameters.
Re-establish proper brake operation wire and return the inspection speed
if changed on the controller.
SETUP OF THE MOTOR LEARN IS NOW COMPLETE!
Scan the QR code to the left to view a walkthrough video of the Motor Tune
Procedure.
4.9. Motor Learn
i

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5
CategoryDC Drives
LanguageEnglish

Related product manuals