86
Diagnostics and Troubleshooting
5. Diagnostics and Troubleshooting
5.1. Diagnostics Screens
Home Screen
Inverter Status Mode
Motor Speed Command Speed
Elevator Speed Motor Current
Diagnostic Screen # 1
Inverter Status Motor Current
DC Bus Voltage Peak Current
Peak DC Volts Magnetizing Current
Diagnostic Screen # 2
Inverter Status Command Speed
Elevator Speed Motor Speed
Peak Speed Modulation Grade
Diagnostic Screen # 3
Inverter Status Motor Speed
Output Condition State Output Frequency
Actual Torque Output Voltage
Diagnostic Screen # 4
Inverter Status Parameter Set
Input Status
Output Status
Diagnostic Screen # 5
Inverter Status Command Speed
Raw Pattern Raw Pretorque
Processed Pattern Post Pretorque
Diagnostic Screen # 6
Inverter Status Mode
Analog Output 1
Analog Output 2
Diagnostic Screen # 7
Heatsink Temperature Motor Current
Motor Temperature Carrier Frequency
Electric Power Motor Power
Diagnostic Screen # 8
Power On Counter Overload Counter
Run Time Counter Drive Load
Braking Energy Peak Load

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5
CategoryDC Drives
LanguageEnglish

Related product manuals