Parameter sets
© KEB, 2015-07 COMBIVERT R6-N Page3.7 - 5
3
10
3.7.5 Copying of parameter sets via bus (Fr.01, Fr.09)
At indirect set addressing two parameters are responsible for copying parameter sets at bus operation. Fr.09
determines the target set. Fr.01 determines the source parameter set and starts the copy process. With direct
set-programming the source set (Fr.01) is copied in the selected parameter sets. The following copy functions
canbeexecuted:
Target
set
Fr.09
Source set
Fr.01
Action
0...7 0...7
All set-programmable parameters (also system parameters) of the source
set are copied in the target set.
0 -1:dEF_S
Default values are copied in all parameters of set 0 (exception system and
security parameters).
1...7 -1:dEF_S
Default values are copied in all set-programmable parameters of the target
set (exception system and security parameters).
All -2:dEF_A
Default values are copied in all parameters of all sets (exception system
and security parameters).
0 -3:ini_S
Default values are copied in all parameters of set 0 (exception security
parameters).
1...7 -3:ini_S
Default values are copied in all set-programmable parameters of the target
set (exception security parameters).
All -4:ini_A
Default values are copied in all parameters of all sets (exception security
parameters).
Alldenitionsdenedbythemachinebuilderareresetbyloadingthefactorysetting! This can include the ter-
minal assignment, set changeover or operating conditions. Ensure before loading the default set that there are