2.2 Password structure
The KEB COMBIVERT is equipped with an extensive password protection. With the individual passwords it is
possible:
- to change the operating mode
- to set a write protection
- to activate the service mode
Dependentontheactualoperationmodethepasswordcanbeenteredinthefollowingparameters:
if the CP mode is activated
if the application mode is activated
2.2.1 Password levels
The parameter value of the parameters above displays the actual password level. The following displays are
possible:
CP - read only
Only the Customer-parameter group is visible,
exept for CP. 0 all parameters are in the read-only
status (see chapter 4.3).
CP - on
Only the customer parameter group is visible. All
parameters can be changed.
CP service
LikeCP-on,howevertheparameteridentication
is displayed in accordance with its origin parameter
(see chapter 4.3)
Application
All application parameters are visible and can be
changed. The CP-Parameters are not visible.