Specifications A- 3
Additional Pulse Mode Source Specifications
MAXIMUM DUTY CYCLE: 8%, hardware limited, 10A range only. All other ranges 100%.
MAXIMUM PULSE WIDTH: 5ms from 90% rising to 90% falling edge, 2.5ms 10A range.
MINIMUM PULSE WIDTH: 150 s.
MINIMUM PULSE RESOLUTION: 50 s typical, 70 s max., limited by system jitter.
SOURCE ACCURACY:Determined by settling time and source range specifications.
OUTPUT SETTLING TIME, 0.1%:
800 s typ., source I = 10A into 10ž, limited by volt age slew rate.
500 s typ., source I = 10A into 1ž, limited by volt age slew rate.
OUTPUT SLEW RATE:Voltage (10ž load): 0.25V/ s ±30% on 100V range
0.08V/ s ±30% on 20V range, 10A range.
Current (0ž load): 0.25A/ s ±30% on 100V range
0.08A/ s ±30% on 20V range, 10A range.
1
S pecifications valid for continuous output current s below 105mA. For operating above 105mA on the 1A range for >1 minute, derate accuracy 10%/100mA
above 105mA. For operating above 105mA on the 3A range for >1 minute, derate accuracy 10%/300mA above 105mA.
2
Full power source operation regardless of load to 30°C. Above 30°C and/or power sink operation, refer to the Power Equations section of the User s Manual.
For power line volt ages less than 95V, limit max. current to 0.85A on 1A range and 2.5A on 3A range.
3
1 0 A range only in pulse mode. Limited to 2.5ms pulse wid th maximum, 8% duty cycle maximum.
Measure Specifications
1, 2, 7
Voltage Measurement Accuracy (remote sense)
Max. Input Accuracy (23°C ± 5°C)
Range Resolution Resist ance 1 Y ear, ±(%rdg + volts)
200.000 m V 1 V >10 Gž 0.012% + 300 V
2.00000 V 10 V >10 Gž 0.012% + 300 V
20.0000 V 100 V >10 Gž 0.015% + 1 m V
100.000 V
7
500 V >10 Gž 0.015% + 5 m V
TEMPERATURE COEFFICIENT (0°–18°C & 28°–50°C):
±(0.15 accuracy specification)/ °C.
Current Measurement Accuracy (local or remote sense)
Max. Voltage Accuracy (23°C ± 5°C)
Range Resolution *Burden
3
1 Year, ±(%rdg + a m p s)
10.0000 A 100 pA < 1mV 0.027% + 700 pA
100.000 A 1 nA < 1mV 0.025% + 6 nA
1.00000 m A 10 nA < 1mV 0.027% + 60 nA
10.0000 m A 100 nA < 1mV 0.035% + 600 nA
100.000 m A 1 A < 1mV 0.055% + 6 A
1.00000 A 10 A < 1mV 0.060% + 120 A
3.00000 A/ 30 A < 1mV 0.052% + 1.71 m A
10.0000 A
6
30 A < 1mV 0.082% + 1.71 m A
TEMPERATURE COEFFICIENT (0°–18°C & 28°–50°C):
±(0.1 accuracy specification)/ °C.
Section A (pgs 1-5).qxd 11/7/2005 1:35 PM Page 3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2430 and is the answer not in the manual?

Keithley 2430 Specifications

General IconGeneral
BrandKeithley
Model2430
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals