7.6
Section 7
Electrical System and Components
Battery Test
Test the baery voltage by connecting a DC voltmeter
across the baery terminals and cranking the engine.
If the baery drops below 9 volts while cranking, the
baery is discharged or faulty. Refer to Figure 7-6.
DC
Voltmeter
Battery
Battery
A 12 volt baery with a minimum current rating
of 250 cold cranking amps is recommended. The
actual cold cranking amp requirement depends on
engine size, application and starting temperatures.
As temperatures decrease, cranking requirements
increase but baery capacity shrinks. Refer to the
operating instructions of the equipment this engine
powers for specic baery requirements.
If the baery charge is not sucient to crank the
engine, recharge the baery. Do not jump start using
another baery.
Battery Charging
WARNING: Explosive Gases!
Baeries produce explosive hydrogen gas while being
charged. To prevent a re or explosion, charge baeries only
in well ventilated areas. Keep sparks, open ames, and other
sources of ignition away from the baery at all times. Keep
baeries out of the reach of children. Remove all jewelry
when servicing baeries.
Before disconnecting the negative (-) ground cable, make
sure all switches are OFF. If ON, a spark will occur at the
ground cable terminal, which could cause an explosion if
hydrogen gas or gasoline vapors are present.
Battery Maintenance
Regular maintenance will ensure the baery will
accept and hold a charge.
1. Regularly check the level of electrolyte. Add
distilled water as necessary to maintain the
recommended level.
NOTE: Do not overll the baery. Poor
performance or early failure due to loss
of electrolyte will result.
2. Keep the cables, terminals, and external surfaces
of the baery clean. A build-up of corrosive
acid or grime on the external surfaces can self-
discharge the baery. Self-discharging happens
rapidly when moisture is present.
3. Wash the cables, terminals, and external surfaces
with a baking soda and water solution. Rinse
thoroughly with clear water.
NOTE: Do not allow the baking soda solution to
enter the cells of the baery, as this will
destroy the electrolyte.
Figure 7-6. Checking Battery Voltage.
Electrical Systems Wiring Diagrams and
Battery Charging Systems
Most engines are equipped with either a 9 or 15 amp,
regulated baery charging system. Some have a 3
amp, regulated system with a 70 wa lighting circuit.
Refer to the following wiring diagrams and
troubleshooting guides to test and service the system.
NOTE: Observe the following guidelines to
prevent damage to the electrical system and
components.
1. Make sure the baery polarity is correct. A
negative (-) ground system is used.
2. Disconnect the baery cables (negative (-) cable
rst), before doing electric welding on the
equipment powered by the engine.
3. Prevent the stator leads from touching or
shorting while the engine is running. This could
damage the stator.

Table of Contents

Other manuals for Kohler Courage SV470

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler Courage SV470 and is the answer not in the manual?

Kohler Courage SV470 Specifications

General IconGeneral
BrandKohler
ModelCourage SV470
CategoryEngine
LanguageEnglish

Related product manuals