TESTING AND ADJUSTING
20-14 EX20 Series
TORQFLOW TRANSMISSION CASE
CHECKING OIL LEVEL
1. Open the inspection window on the floor plate and
check the oil level with the oil gauge.
2. If the oil level is low, remove the oil filler plug and add
oil.
CHANGING OIL, CLEANING STRAINER
1. Remove the drain plug, drain the oil, then tighten the
drain plug.
2. Remove the pipe, take out the strainer, and wash it in
flushing oil.
3. After washing, blow the strainer with compressed air
from the inside to dry it completely, then install it .
4. Add oil through the oil filler plug to the specified level.
5. After adding oil, check the oil level.
Oil change amount: 28
(7.397 USgal, 6.159 UKgal)
NOTICE:
Always use SAE 10W–CD oil for the engine oil. (For
details, see FUEL AND LUBRICANTS.)
CAUTION
The oil is at high temperature immediately after
stopping work. Wait for the temperature to go down
before starting the operation.
Strainer
Oil gaugeOil filler cap
Correct
range
Drain plug
TORQFLOW TRANSMISSION CASE