METHOD FOR REPLACING HYDRAULIC TANK BREATHER ELEMENT
kk
WARNING
• Immediately
after the engine is stopped, its parts and oil are still very hot and may cause burn in-
jury.
Wait for the temperature to go down, and then start the work.
• When removing the oil filler cap, the oil may spurt out. Turn it slowly to release the internal pres-
sure, then remove it carefully.
1.
Open the dirt cover (1).
Open
the dirt cover (1) fully and it will be secured by the
cover support lever (2).
2.
Loosen the bolt (3) of the hydraulic tank, move the plate
(4)
on the oil filler port (F), and turn the cap of the oil filler
port (F) slowly to remove it.
Release the internal pressure.
3.
Remove the nut (6) of breather (5), and then remove the
cover (7).
Use a tool when nut (6) is too tight to remove.
4.
Replace the element (8) with a new element.
5.
Install the cover (7) and nut (6).
In order not to damage the threaded portion of nut, tighten
the
nut (6) by hand until it is seated, then retighten it 15 to
30 ° by using a tool.
6.
Start the engine.
7.
Set the lock lever to FREE position (F).
Be sure to operate the lock lever by the operating portion
on the top.
MAINTENANCE PROCEDURE MAINTENANCE
4-80

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Komatsu PC45MR-5 and is the answer not in the manual?

Komatsu PC45MR-5 Specifications

General IconGeneral
BrandKomatsu
ModelPC45MR-5
CategoryExcavators
LanguageEnglish

Related product manuals