8-S14
F2880, F3680, RCK72-F36, RCK72R-F36, RCK60-F36, RCK60R-F36, WSM
ELECTRICAL SYSTEM
(10) Cooling System
Coolant Temperature Switch Connector Voltage
1. Disconnect the 1P connector from the thermo switch (1).
2. Turn the main switch key to the "ON" position, and measure the
voltage with a voltmeter between the connector terminal and the
chassis.
3. If no voltage is indicated, the wiring harness is faulty.
W1019979
Thermo Switch Continuity
1. Disconnect the 1P connector, and remove the thermo switch.
2. Using an ohmmeter, check for continuity between the switch
terminal and the chassis.
3. If infinity is indicated at temperature over factory specifications,
the switch is faulty.
W1020328
(11) Gauges
Fuel Level Sensor
1. Remove the fuel level sensor from the fuel tank.
2. Measure the resistance with an ohmmeter across the sensor
terminal and its body.
3. If the reference value are not indicated, the sensor is faulty
W1020613
Voltage (Connector
terminal - Chassis)
Factory spec. Positive voltage
(1) Thermo Switch
Working temperature Factory spec.
120 to 126 °C
248.0 to 258.8 °F
(A) ON
(B) OFF
(C) 120 to 126 °C (248.0 to 258.8 °F)
(D) 116 °C (240.8 °F) or more
Resistance
(Sensor terminal -
Chassis)
Reference
value
Float at
upper-most
position
1 to 5 Ω
Float at
lower-most
position
103 to 117 Ω
(1) Fuel Level Sensor E : Empty
F : Full