10.2 Parameter list | C00114
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00114
C00118
Parameter | Name:
C00114 | DIx inversion
Data type: UNSIGNED_16
Index: 24461
d
= 5F8D
h
Polarity of the digital inputs
• Every digital input of the device can be inverted with regard to polarity via this bit field.
Digital terminals
Setting range (min. hex value | max. hex value) Lenze setting
0x0000 0xFFFF 0x8000 (decimal: 32768)
Value is bit-coded: ( =bit set) Info
Bit 0 DI1 inverted Inversion of digital input 1
Bit 1 DI2 inverted Inversion of digital input 2
Bit 2 DI3 inverted Inversion of digital input 3
Bit 3 DI4 inverted Inversion of digital input 4
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 RFR inverted Inversion of RFR digital input (controller enable)
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00118 | DOx inversion
Data type: UNSIGNED_8
Index: 24457
d
= 5F89
h
Polarity of the digital outputs
• Every digital output of the device can be inverted with regard to polarity via this bit field.
Digital terminals
Setting range (min. hex value | max. hex value) Lenze setting
0x00 0xFF 0x00 (decimal: 0)
Value is bit-coded: ( =bit set) Info
Bit 0 Relay inverted Relay inversion
Bit 1 DO1 inverted Inversion of digital output 1
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT