TESTING
Test 1 – Battery Test (12 and 24 volts DC)
Test the 12-volt DC accessory system voltage with a digital
multi-meter. Record the voltage before and during engine
cranking.
A voltage reading of 12 volts or less before cranking engine
may indicate a charging system fault. A drop of 4 volts or
more indicates the battery is failing.
Test the 12-volt DC starting batteries in series for 24 volts
using a digital multi-meter. Record the voltage before and
during engine cranking.
A voltage reading of 24 volts or less before cranking engine
may indicate a charging system fault. A drop of 8 volts or
more indicates the battery is failing.
Item
Description
Item
Description
1 Positive Lead 2 Negative Lead
21
AA301
12 VDC
P1616
2
1
24 VDC
Item
Description
Item
Description
1 Positive Lead 2 Negative Lead

Table of Contents

Other manuals for Manitowoc 999

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 999 and is the answer not in the manual?

Manitowoc 999 Specifications

General IconGeneral
BrandManitowoc
Model999
CategoryConstruction Equipment
LanguageEnglish

Related product manuals