Published 4-20-2015, Control # 502-01 4-41
RT540E SERVICE MANUAL BOOM
4
GROVE
Boom lowers
slowly. (Continued)
j. Worn hydraulic pump section. j. Repair or replace pump section.
k. Piston rod broken (loose from piston). k. Replace piston rod and all cylinder
seals.
5. Boom will not raise. a. Low hydraulic oil. a. Replenish hydraulic oil to proper level.
b. Main relief valve or circuit relief valve
damaged.
b. Repair or replace relief valve.
c. Excessive load. c. Reduce load as required.
d. Worn or damaged hydraulic pump
section.
d. Repair or replace pump section.
e. Broken pump shaft. e. Replace pump shaft and seals.
f. Broken pump drive coupling. f. Replace drive coupling.
g. Broken control valve spool. g. Replace control valve.
6. Boom will not
lower.
a. Low hydraulic oil. a. Replenish hydraulic oil to proper level.
b. Main relief valve or circuit relief valve
damaged.
b. Repair or replace relief valve.
c. Worn or damaged hydraulic pump
section.
c. Repair or replace pump section.
d. Broken pump shaft. d. Replace pump shaft and seals.
e. Broken pump drive coupling. e. Replace drive coupling.
f. Broken control valve spool. f. Replace control valve.
Symptom Probable Cause Solution
Reference Only

Table of Contents

Other manuals for Manitowoc Grove RT540E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT540E and is the answer not in the manual?

Manitowoc Grove RT540E Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT540E
CategoryConstruction Equipment
LanguageEnglish

Related product manuals