DISASSEMBLY PROCEDURE
PHOTOS
96
19. How to remove the scale trap (sanitary circuit)
(1) Remove the front panel (Refer to Procedure 1).
(2) Disconnect the CNP4 connector and the earth cable in
thecontrolbox.(Photo4-1)
(3)Releasethewaterpumpleadwirefromthe2cable
clampsandthecablestrapinthecontrolbox,the2
cablestrapsandthe3bandsbelowthecontrolbox.
(Photos 4-1 and 10-1)
(4) Remove the P-HEX (Water-Water) (Refer to Procedure
17).
(5)Removethe3screwsandtheplate(underP-HEX
(W-W)). (Photo 19-1)
(6)Removethepipe(Tank-P-HEX(W-W))byremovingthe
G3/4"nut.(Photo19-1)
•
WhenreinstallingtheG3/4"nut,useanewG3/4"gasket.
(7)RemovetheG3/4"nutandquickconnectionclipfromthe
pipe (W.P. - Tank).
(Photo 19-2)
•
WhenreinstallingtheG3/4"nut,useanewG3/4"gasket.
(8)RemovethescrewwhichfixestheS.T.support.(Photo
19-3)
•Ifthereisnotenoughspacetouseascrewdriver,
rotatethepipe(W.P.-Tank)forwardwithauseofthe
quick connection part as a fulcrum.
(9)
Removethe2screws(Rightside).(Photos19-1and19-2)
(10)Removethescaletrapwiththewaterpump,pipesand
the S.T. support.
(Photo 19-4)
(11) Remove the
G1"nut,thescrewsandthesaddleband,
then remove the scale trap.
(Photo 19-4)
•WhenreinstallingtheG1"nut,useanewG1"gasket.
•Reusethesaddlebandandthescrews.
•Reusethe
S.T. support.
Photo 19-1
Photo 19-2
Photo 19-3
Photo 19-4
Scale trap
Water pump
Nut(G1")
S.T. support
Screws
Saddle band
Pipe (Water pump
- DHW tank)
Nut(G3/4"),
Gasket(G3/4")
Pipe (Tank - P-HEX
(W-W))
Screws
Plate (under P-HEX
(W-W))
Screwfixingthe
S.T. support
Nut(G3/4")
Pipe (W.P. - Tank)
Quickconnection
clip
Water pump
Screw(right
side)
Screwfixing
the S.T.
support
Pipe
(W.P. - Tank)
Gasket(G1")
Screw
(rightside)