11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 8
11.2.2 Selection of regenerative option
(1) Rotary servo motor and direct drive motor
Use the following method when regeneration occurs continuously in vertical motion applications or when
it is desired to make an in-depth selection of the regenerative option.
(a) Regenerative energy calculation
M
Friction
torque
Unbalance torque
TF
TU
Servo motor speedGenerated torque
Time
Up
V
tf (1 cycle)
Down
(+)
(-)
(Power running)
(Regenerative)
tpsd2
t2 t3 t4t1
tpsa2tpsd1
tpsa1
1)
2)
3)
4)
5)
6)
7)
8)
Formulas for calculating torque and energy in operation
Regenerative
power
Torque applied to servo motor [N•m] Energy E [J]
1)
T
1
=
(JL/η + J
M
) • V
9.55 • 10
4
•
t
psa1
1
+ T
U
+ T
F
E
1
=
2
0.1047
• V • T
1
• t
psa1
2) T
2
= T
U
+ T
F
E
2
= 0.1047 • V • T
2
• t
1
3)
T
3
=
-(JL • η + J
M
) • V
9.55 • 10
4
•
t
psa2
1
+ T
U
+ T
F
E
3
=
2
0.1047
• V • T
3
• t
psa2
4), 8) T
4
, T
8
= T
U
E
4
, E
8
= 0 (No regeneration)
5)
T
5
=
(JL/η + J
M
) • V
9.55 • 10
4
•
t
psd2
1
- T
U
+ T
F
E
5
=
2
0.1047
• V • T
5
• t
psd2
6) T
6
= -T
U
+ T
F
E
6
= 0.1047 • V • T
6
• t
3
7)
T
7
=
-(JL • η + J
M
) • V
9.55 • 10
4
•
t
psd2
1
- T
U
+ T
F
E
7
=
2
0.1047
• V • T
7
• t
psd2
From the calculation results in 1) to 8), find the absolute value (Es) of the sum total of negative
energies.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MR-J4-70A and is the answer not in the manual?

Mitsubishi MR-J4-70A Specifications

General IconGeneral
BrandMitsubishi
ModelMR-J4-70A
CategoryAmplifier
LanguageEnglish

Related product manuals