14. COMMUNICATION FUNCTION
14 - 30
14.5.8 Test operation mode
POINT
The test operation mode is used to check operation. Do not use it for actual
operation.
If communication stops for longer than 0.5 s during test operation, the servo
amplifier decelerates to a stop, resulting in servo-lock. To prevent this, continue
communication all the time by monitoring the status display, etc.
Even during operation, you can switch the servo amplifier to the test operation
mode. In this case, switching to the test operation mode will shut off the base
circuit to coast the motor.
(1) How to prepare and cancel the test operation mode
(a) Preparing the test operation mode
Set the test operation mode type with the following procedure.
1) Selection of test operation mode
Send the command [8] [B] + data No. [0] [0] + data to select the test operation mode.
Command Data No.
Transmission
data
Selection of test operation mode
0001 JOG operation
0002 Positioning operation
[8] [B] [0] [0]
0004 Output signal (DO) forced output (Note)
Note. Refer to section 14.5.9 for output signal (DO) forced output.
2) Check of test operation mode
Read the test operation mode set for the slave station, and check that it is set correctly.
a) Transmission
Transmit command [0] [0] and data No. [1] [2].
Command Data No.
[0] [0] [1] [2]
b) Reply
The slave station returns the preset operation mode.
00
Test operation mode reading
0: Normal mode (not test operation mode)
1: JOG operation
2: Positioning operation
3: Motor-less operation
4: Output signal (DO) forced output
0
(b) Cancel of test operation mode
To terminate the test operation mode, send the command [8] [B] + data No. [0] [0] + data.
Command Data No.
Transmission
data
Selection of test operation mode
[8] [B] [0] [0] 0000 Test operation mode cancel