11.16 EMC filter (recommended)
It is recommended that one of the following filters be used to comply with EN standard's EMC directive.
Some EMC filters have large in leakage current.
(1) Combination with the servo amplifier
Recommended filter (Soshin Electric)
Servo amplifier
Model Rated current [A]
Rated voltage
[V AC]
Leakage current
[mA]
Mass [kg]
MR-J4-10A(-RJ) to
MR-J4-100A(-RJ)
(Note)
HF3010A-UN
10 3.5
MR-J4-200A(-RJ)
MR-J4-350A(-RJ)
(Note)
HF3030A-UN
30
5
5.5
MR-J4-500A(-RJ)
MR-J4-700A(-RJ)
(Note)
HF3040A-UN
40 6
MR-J4-11KA(-RJ)
MR-J4-15KA(-RJ)
MR-J4-22KA(-RJ)
(Note)
HF3100A-UN
100
250
6.5
12
MR-J4-60A4(-RJ)
MR-J4-100A4(-RJ)
TF3005C-TX 5
MR-J4-200A4(-RJ) to
MR-J4-700A4(-RJ)
TF3020C-TX 20
6
MR-J4-11KA4(-RJ) TF3030C-TX 30 7.5
MR-J4-15KA4(-RJ) TF3040C-TX 40
MR-J4-22KA4(-RJ) TF3060C-TX 60
500 5.5
12.5
Note. A surge protector is separately required to use any of these EMC filters.
(2) Connection example
(a) 200 V class
MCCB
L1
L2
L3
L11
L21
Servo amplifie
r
1
2
3
4
5
6
E
(Note 2)
Surge protector
(RSPD-250-U4)
(OKAYA Electric Industries Co., Ltd.)
(Note 1)
Power supply
123
MC
EMC filter
Note 1. For 1-phase 200 V AC to 240 V AC, connect the power supply to L1 and L3.
Leave L2 open.
2. The example is when a surge protector is connected.
(b) 400 V class
MCCB
Servo amplifier
1
2
3
Power
suppl
y
MC
EMC filte
r
L1
L2
L3
L11
L21
4
5
6
E

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MR-J4-70A and is the answer not in the manual?

Mitsubishi MR-J4-70A Specifications

General IconGeneral
BrandMitsubishi
ModelMR-J4-70A
CategoryAmplifier
LanguageEnglish

Related product manuals