121 / 195
Service Manual Mitsubishi SL-Series diesel engines
Version 08/2004
STARTER
ENGLISH
ELECTRICAL SYSTEM
29.4.3 Solenoid Switch
Perform the following continuity tests. If the solenoid
switch fails either tests, replace it.
1) Test for Coil Open Circuit
Continuity should exists between the S- and
M-terminals and between the S-terminal and
ground (case).
2) Test for Fused Contacts
Continuity should not exist between the B-
and M-terminals.
Voltage
(V)
Current
(A)
Speed
(min
-1
)
No-Load
characteristics
11 130
maximum
3,600
minimum
M-terminal
S-terminal
B-terminal