ALTERNATOR ELECTRICAL SYSTEM
124 / 195
30.2 Inspection
30.2.1 Diodes
1. Test the resistance between the diode and heat
sink. First touch the positive (+) prod of an
ohmmeter to the diode, then the negative (–) prod.
If the resistance is infinite in both cases, the diode
is open. If it is nearly zero in both cases, the diode
is shorted. Do the same step for the remainder of
the diodes. If any diode is open or shorted,
replace the rectifier.
Figure 187 Inspection points
Test for open or short
circuit using theprocedure
that follows.
Test for open or short
circuit usingthe procedure
that follows.
Check for cracks or
other defects.
Check for cracks or
other defects.
Check for wear.
Test for open or short
circuit using the
procedure that follows.
Figure 188 Testing diode
Heat sink (+)
Diode lead wires
Heat sink (-)
Trio-diodes