Apex Classic Setup and Programming Guide v2.2 Page 98
MINIMUM TIME
The Minimum Time command will keep an outlet in the on or off state for a
minimum amount of time. To use this command, specify the amount of time you
would like it to be in effect and whether you want it to keep the outlet off or on.
Both a Minimum on and a minimum off time can be specified on a given outlet.
Min Time 010 Then OFF
In this example, the outlet will be kept in the off state for a minimum of 10
minutes.
Syntax
Min Time MMM:SS then Y
MMM = time in minutes:seconds up to 999:59 max
Y = ON to keep the outlet on or OFF to keep the outlet off
OSC
The OSC command is used to program an outlet to periodically turn on and off.
This is typically used to perform wave maker functions.
OSC 010:00/015:00/05:00 Then ON
In this example, the outlet will be off for 10 minutes, on for 15 minutes, off for 5
minutes, repeats with on of 15 minutes.
Syntax
OSC FFF:FF/SSS:SS/TTT:TT Then Y
FFF:FF = the initial off time in minutes:seconds up to 999:59 max
SSS:SS= the first on time in minutes:seconds up to 999:59 max
TTT:TT = the second Off time in minutes:seconds up to 999:59 max
Y = ON to turn the outlet on or OFF to turn the outlet off

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Neptune Systems AquaController Apex Classic and is the answer not in the manual?

Neptune Systems AquaController Apex Classic Specifications

General IconGeneral
BrandNeptune Systems
ModelAquaController Apex Classic
CategoryControl Unit
LanguageEnglish