Apex Classic Setup and Programming Guide v2.2 Page 61
If Temp > RT+0.2 then OFF
This will turn the heater outlet on when the Temp probe measures the Regional
Temperature less .3 degrees. The heater outlet will turn off at Regional
Temperature plus .2 degrees.
The following command could be used to trigger an alarm:
If Temp > RT+2 Then ON
This will turn on the alarm when the aquarium temperature reaches 2 degrees
above the Regional Temperature set point.
SEASONAL LIGHTING ADJUSTMENT
The AquaController Apex can simulate the varying lengths of daylight during the
seasons of the year based upon a typical tropical reef at 15° north latitude. The If
Sun command is used to turn outlets on and off that automatically adjust to
these seasonal adjustments throughout the year. An offset from the standard
time is provided so multiple lights can be cycled on and off in sequence. The
following commands could be used to control a light on a system:
Light1:
If Sun 000/000 Then ON

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Neptune Systems AquaController Apex Classic and is the answer not in the manual?

Neptune Systems AquaController Apex Classic Specifications

General IconGeneral
BrandNeptune Systems
ModelAquaController Apex Classic
CategoryControl Unit
LanguageEnglish