Technical Data
8-2
Part 1073401_07
E 2021 Nordson Corporation
Electrical Specifications
NOTE: Refer to Connecting the Electrical Service in Section 3, Installation,
for maximum amperage specifications.
Item Data Note
Hose/applicator heating capacity 2 hose/applicator pairs
Control temperature range (240 and 120 VAC) 40 to 230 °C (100 to 450 °F)
Control temperature accuracy 0.5 °C ( 1 °F)
IP rating IP 32
Heater Specifications
NOTE: Refer to the hose and applicator manuals for hose/applicator heater
specifications.
Location Voltage
Wattage
(see Note A)
Cold Resistance
(see Note B)
Pump 120 V 300 43.4-50.7 ohms
Tank, D4L 120 V 2 x 425 30.7-35.8 ohms each
Tank, D10L/D16L 120 V 2 x 450 29.0-33.8 ohms each
Pump 240 V 400 130-152 ohms
Tank, D4L 240 V 2 x 425 123-143 ohms each
Tank, D10L 240 V 2 x 650 80.2-93.5 ohms each
Tank, D16L 240 V 2 x 900 57.9-67.6 ohms each
NOTE A: Nominal wattage at 177-204 _C (350-400 _F).
B: Measured at room temperature for a previously heated element.

Table of Contents

Other manuals for Nordson DuraBlue D4L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson DuraBlue D4L and is the answer not in the manual?

Nordson DuraBlue D4L Specifications

General IconGeneral
BrandNordson
ModelDuraBlue D4L
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals