Tank key
Left display and
scroll key
Installation
3-18
Part 1073401_07
E 2021 Nordson Corporation
Setpoint Temperature of the Tank, Hoses, and Applicators
The melter is shipped from the factory with the tank setpoint temperature at
175 °C (350 °F) and the hose and applicator setpoint temperatures at 0
degrees (turned off).
Before the melter can be used, a setpoint temperature must be assigned to
the tank, hoses, and applicators. Assign setpoint temperatures using any of
the following methods:
S Global—The tank and all hoses and applicators are set to the same
setpoint temperature.
S Global‐by‐component group—All of the hoses or all of the applicators
are set to the same setpoint temperature.
S Individual Component—The setpoint temperature of the tank and each
hose and applicator is set individually.
Since most manufacturing processes will require the tank, hoses, and
applicators to be set to the same temperature, only the global method of
assigning setpoint temperatures is described in this section. For information
about the other two methods of assigning setpoint temperatures, refer to
Adjusting Component Temperatures in Section 4, Operation.
As with operating parameters, you can also review past changes that were
made to setpoint temperatures.
To assign a global setpoint temperature
1. Press and hold the Tank key for three seconds.
The left display flashes 1.
2. Scroll the left display to 0.
The right display indicates all dashes (‐‐‐‐) and the LEDs on the tank,
hose, and applicator keys turn green.
3. Press a right‐display scroll key.
The right display flashes.