Technical Data
8-3
Part 1073401_07
E 2021 Nordson Corporation
Motor and Pump Specifications
Item Data Note
Viscosity Range
Melter with filter 1000–30000 cps.
Melter without filter 1000–10000 cps
Maximum hydraulic pressure
Melter with filter 75 bar (1100 psi)
Melter without filter 40 bar ( 600 psi)
Displacement 7.8 cc/rev
Motor speed
1
/
6
hp 54.6 rpm at 60 Hz or 45 rpm at 50 Hz
1
/
4
hp
86.25 or 138 rpm at 60 Hz
71.25 or 114 rpm at 50 Hz
A
NOTE A: Depends on gear reducer used