5-1 Going Online
5
5
SYSMAC CP1L/CP1E Introduction Manual 87
5
Transferring and Debugging Programs
2. Click [Yes].
The operating mode will be changed.
o
The operating mode will be displayed on the title bar and on the project tree.
CP1L Operating Mode
CP1L has 3 operating modes: PROGRAM, MONITOR, and RUN. Change the
operating mode to reflect the operation to be performed. The operation mode
affects the whole user program, and is common to all tasks.
PROGRAM mode:
In this state, the program is stopped. This mode is used to prepare for program
execution by performing initial settings such as PLC setup, transferring the
program, checking the program, and force-setting/force-resetting.
MONITOR mode:
In this state, the program is executed. You can perform online editing, force-set/
force-reset, and change I/O memory values. This mode is also used for making
adjustments during test runs.
RUN mode:
In this state, the program is executed. Use this mode for production runs.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CP1E - INTRODUCTION and is the answer not in the manual?

Omron CP1E - INTRODUCTION Specifications

General IconGeneral
BrandOmron
ModelCP1E - INTRODUCTION
CategoryController
LanguageEnglish

Related product manuals