5-1 Going Online
5
5
SYSMAC CP1L/CP1E Introduction Manual 87
5
Transferring and Debugging Programs
2. Click [Yes].
The operating mode will be changed.
o
The operating mode will be displayed on the title bar and on the project tree.
CP1L Operating Mode
CP1L has 3 operating modes: PROGRAM, MONITOR, and RUN. Change the
operating mode to reflect the operation to be performed. The operation mode
affects the whole user program, and is common to all tasks.
PROGRAM mode:
In this state, the program is stopped. This mode is used to prepare for program
execution by performing initial settings such as PLC setup, transferring the
program, checking the program, and force-setting/force-resetting.
MONITOR mode:
In this state, the program is executed. You can perform online editing, force-set/
force-reset, and change I/O memory values. This mode is also used for making
adjustments during test runs.
RUN mode:
In this state, the program is executed. Use this mode for production runs.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Omron CP1E - INTRODUCTION and is the answer not in the manual?

Omron CP1E - INTRODUCTION Specifications

General IconGeneral
SeriesCP1E
ManufacturerOmron
Input Voltage100 to 240 VAC or 24 VDC (depending on model)
I/O Points10 to 60 points
Number of Inputs6 to 36 points
Number of Outputs4 to 24 points
Communication PortsUSB, RS-232C
Programming LanguageLadder Diagram (LD)
Power Supply100-240V AC or 24V DC
Storage Temperature-25°C to 65°C
Vibration Resistance10 to 57 Hz, 0.075mm amplitude
Shock Resistance147 m/s², 3 times each in X, Y, Z directions
WeightVaries by model
TypeProgrammable Logic Controller (PLC)

Summary

Introduction and Preliminary Information

Precautions and Safety Guidelines

Details essential precautions, intended audience, safety measures, and application guidelines for safe operation.

Section 1: CP1L/CP1E Overview

Section 2: Designing Systems

Section 3: Mounting and Wiring

Section 4: Creating Programs

Ladder Program Creation Process

Explains how to construct ladder programs for the shutter control system example.

Using CX-Programmer Software

Covers starting and navigating the CX-Programmer software interface for program development.

Inputting and Editing Program Elements

Step-by-step guide to entering ladder logic elements and modifying comments and rungs.

Section 5: Transferring and Debugging Programs

Establishing Online Connection

Describes establishing a connection between the computer and CP1L for program transfer and monitoring.

Program Transfer and Execution

Step-by-step process for transferring programs from CX-Programmer to CP1L and executing them.

Online Adjusting and Debugging Techniques

Covers monitoring, force-setting, searching, and online editing for efficient debugging.