160
Protect Level Section 5-2
The password to move to the protect level is entered for this parameter.
• The password to move to the protect level (i.e., the password set for the
Password to Move to Protect Level parameter) is entered for this parame-
ter.
• The Operation/Adjustment Protect parameter will be displayed if the cor-
rect password is entered.
â–  Related Parameters
Password to move to protect level (protect level): Page 162
These parameters specify the range of parameters to be protected. Shaded
settings are the defaults.
â–  Operation/Adjustment Protect
The following table shows the relationship between set values and the range
of protection.
• Parameters are not protected when the set value is set to 0.
â–  Initial Setting/Communications Protect
This protect level restricts movement to the initial setting level, communica-
tions setting level, and advanced function setting level.
pmov Move to Protect Level
The Password to Move to Protect
Level password must not be set to 0.
Function
See
See
oapt Operation/Adjustment Protect
icpt Initial Setting/Communications Protect
Function
Setting
Level Set value
0123
Operation
Level
PV Can be displayed Can be displayed Can be displayed Can be displayed
PV/SP Can be displayed
and changed
Can be displayed
and changed
Can be displayed
and changed
Can be displayed
Others Can be displayed
and changed
Can be displayed
and changed
Cannot be dis-
played and moving
to other levels is
not possible
Cannot be dis-
played and moving
to other levels is
not possible
Adjustment Level Can be displayed
and changed
Cannot be dis-
played and moving
to other levels is
not possible
Cannot be dis-
played and moving
to other levels is
not possible
Cannot be dis-
played and moving
to other levels is
not possible
Set
value
Initial setting level Communications
setting level
Advanced function
setting level
0 Possible to reach Possible to reach Possible to reach
1 Possible to reach Possible to reach Not possible to reach
2 Not possible to reach Not possible to reach Not possible to reach

Table of Contents

Other manuals for Omron E5AN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E5AN and is the answer not in the manual?

Omron E5AN Specifications

General IconGeneral
BrandOmron
ModelE5AN
CategoryTemperature Controller
LanguageEnglish

Related product manuals