7 System-defined Variables That Are Related to the Built-in EtherCAT Port
7-16
NJ/NX-series CPU Unit Built-in EtherCAT Port User’s Manual (W505)
Note All system-defined variables that are related to the status of EtherCAT communications give the current status.
Note All system-defined variables that are related to the status of EtherCAT communications give the current status.
Note All system-defined variables that are related to the status of EtherCAT communications give the current status.
Functional Classification: EtherCAT Communications Diagnosis/Statistics
Log
* This system-defined variable was added for unit version 1.11 of the CPU Unit.
Variable name _EC_InDataInvalid
Meaning Input Data Invalid Global/local Global
Function TRUE when process data communications are not normal and the input data is not valid.
Data type BOOL Range of values TRUE or FALSE
R/W access R Retained Not retained. Network Publish Published.
Usage in user program Possible. Related instruc-
tions
---
Variable name _EC_InData1Invalid
Meaning Input Data1 Invalid Global/local Global
Function TRUE when process data communications established in the primary periodic period are not normal and the input
data is not valid.
You can use this system-defined variable only for NX-series CPU Units.
Data type BOOL Range of values TRUE or FALSE
R/W access R Retained Not retained. Network Publish Published.
Usage in user program Possible. Related instruc-
tions
---
Variable name _EC_InData2Invalid
Meaning Input Data2 Invalid Global/local Global
Function TRUE when process data communications established in the priority-5 periodic period are not normal and the
input data is not valid.
Note You can use this system-defined variable only for NX-series CPU Units.
Note This variable is always TRUE for NX102 and NX1P2 CPU Units.
Data type BOOL Range of values TRUE or FALSE
R/W access R Retained Not retained. Network Publish Published.
Usage in user program Possible. Related instruc-
tions
---
Variable name
_EC_StatisticsLogEnable
*
Meaning Diagnosis/Statistics Log Enable Global/local Global
Function Changes to TRUE when the diagnosis/statistics log is started.
Changes to FALSE when the diagnosis/statistics log is ended.
Data type BOOL Range of values TRUE or FALSE
R/W access R/W Retained Not retained. Network Publish Published.
Usage in user program Possible. Related instruc-
tions
---

Table of Contents

Other manuals for Omron NX102 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NX102 series and is the answer not in the manual?

Omron NX102 series Specifications

General IconGeneral
BrandOmron
ModelNX102 series
CategoryController
LanguageEnglish

Related product manuals