EasyManuals Logo
Home>Omron>Controller>NX102 series

Omron NX102 series User Manual

Omron NX102 series
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #220 background imageLoading...
Page #220 background image
Appendices
A-6
NJ/NX-series CPU Unit Built-in EtherCAT Port User’s Manual (W505)
A-1-4 Others
CPU Unit sta-
tus
Memory related to EtherCAT master
Down-
loading
master
and slaves
settings
Slaves
Device
variables
Category
_EC sys-
tem-
defined
variables
Network
configura-
tion infor-
mation
Diagnos-
tic and
statistical
informa-
tion/Proto-
col
monitor
Current
errors
Slave out-
puts
Slave
communi-
cations
status
Memory all
clear
Cleared to
all zeros.
Entirely ini-
tialized (0).
Deleted. Cleared to
all zeros.
Cleared to
all zeros.
--- Depends
on the
slave set-
tings.
Enters the
Initialized
state.
Download-
ing data
and
Device Out-
put Hold
Configura-
tion
*1
dis-
abled
*1 Refer to the NJ/NX-series CPU Unit Software User’s Manual (Cat. No. W501) for the Device Output Hold Configuration.
Device
variables
that are not
retained:
Initial val-
ues
Axis vari-
ables: Ini-
tial values
Continu-
ally shows
EtherCAT
communi-
cations sta-
tus. (Does
not depend
on the
operating
mode of
the CPU
Unit.)
Does not
change.
(Does not
depend on
the operat-
ing mode
of the CPU
Unit.)
Cleared to
all zeros.
Cleared to
all zeros.
(However,
after down-
loading
data, the
EtherCAT
master
restarts,
and
records
any event
as a cur-
rent error if
the cause
of the error
has not
been
removed.)
Enters
the Ini-
tialized
state
when
parame-
ters are
trans-
ferred to
the mas-
ter.
Enters
the Pre-
opera-
tional
state
when
backup
parame-
ters are
down-
loaded to
slaves.
Download-
ing data
and
Device Out-
put Hold
Configura-
tion enabled
Device
variables
that are not
retained:
Retained
Axis vari-
ables:
Retained
Continu-
ally shows
EtherCAT
communi-
cations sta-
tus. (Does
not depend
on the
operating
mode of
the CPU
Unit.)
Retained
(Do not
depend on
the operat-
ing mode
of the CPU
Unit.)
Continu-
ally shows
the output
data sent
from the
EtherCAT
master.
(Does not
depend on
the operat-
ing mode
of the CPU
Unit.)
Does not
change.
(Does not
depend on
the operat-
ing mode
of the CPU
Unit.)

Table of Contents

Other manuals for Omron NX102 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NX102 series and is the answer not in the manual?

Omron NX102 series Specifications

General IconGeneral
BrandOmron
ModelNX102 series
CategoryController
LanguageEnglish

Related product manuals