9-27
9 Troubleshooting
NJ/NX-series CPU Unit Built-in EtherCAT Port User’s Manual (W505)
9-4 Replacing Slaves during Communications
9
9-4-1 Introduction
9-4 Replacing Slaves during
Communications
You can temporarily stop and start communications with a specified slave and all subsequent slaves
without stopping the entire communications system. This makes it possible to replace slaves during
communications for maintenance, or for replacement when a slave malfunctions.
Precautions for Correct UsePrecautions for Correct Use
A Process Data Communications Error occurs if you physically disconnect a slave from the
network without executing the disconnection instruction.
A Network Configuration Verification Error occurs if the correct node address is not set for a
slave that was replaced with the disconnection instruction and a connection is made to a dif-
ferent port than the one that was used for the disconnection instruction.
9-4-1 Introduction
NJ/NX-series CPU Unit
Slave
Slave
EtherCAT communications
instruction
Slave
EC_Disconnect
Slave
New slave
Specified from the Sysmac Studio or
with an instruction for EtherCAT
communications.
Sysmac Studio
Replaced.
Slave you
need to replace
Communications continue.
Communications stop.

Table of Contents

Other manuals for Omron NX102 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NX102 series and is the answer not in the manual?

Omron NX102 series Specifications

General IconGeneral
BrandOmron
ModelNX102 series
CategoryController
LanguageEnglish

Related product manuals