2-17
2 Part Names and Slave Settings
NJ/NX-series CPU Unit Built-in EtherCAT Port User’s Manual (W505)
2-3 Features of Sysmac Devices
2
2-3-4 Sysmac Device Features and EtherCAT Masters
*7 The ability to verify serial numbers depends on the ability of the EtherCAT master from another manufacturer.
If you connect slaves from other manufacturers to an OMRON EtherCAT master, some slave functions
are not supported or restricted as follows.
• When you use an ESI file that is not supported by the Sysmac Studio, some slave functions may be
restricted or not settable, or the slave may not operate properly.
• The node address setting from the Sysmac Studio may not be supported by some slave specifica-
tions.
• Verification with serial numbers is not possible for slaves that do not have the serial number in SII.
Slaves from Other Manufacturers