Load Display Command
August 2016 Commands 57
Load Display Command
The Load Display command (vendor specific) displays ASCII messages on the virtual
operator panel for that device. This command transfers 17 bytes of data to the
display. The data transferred contains one byte of display control data and two, eight-
byte ASCII messages.
Load Display Data Format
Notes:
• Messages in bytes 1–8 and 9–16 use the ASCII printable character set.
• Non-printable characters are displayed as blanks.
• The format control byte controls the way the device displays the remaining 16
bytes.
TABLE 3-19 Load Display Command
Byte
Bit
76543210
0 Operation Code (06h)
1 Reserved
2 Reserved
3 Reserved
4 Transfer Length (11h)
5 Control Byte
TABLE 3-20 Load Display Data Bytes
Byte
Bit
76543210
0 Overlay Alt Blink L/H Reserved
1
thru
8
(MSB)
(ASCII) Message 1
(LSB)
9
thru
16
(MSB)
(ASCII) Message 2
(LSB)