Log Sense Command
70 T10000: Interface Reference Manual August 2016
Write Error Counter Page
The Write Error Counter page (02h) reports write statistical errors. Each parameter is
a counter incriminated by the target each time a corresponding event occurs.
TABLE 3-34 Write Error Counter Page Codes
Parameter
Code Description
Length
(bytes)
Default
Threshold
0000h Errors corrected without substantial delays 4 FFFFFFFF
0001h Errors corrected with possible delays 4 FFFFFFFF
0002h Total number of re-writes 4 FFFFFFFF
0003h Number of records with a recovered data check
while writing
4 FFFFFFFF
0004h Always 0 4 FFFFFFFF
0005h Number of non–compressed bytes transferred from
the initiator
8 FFFFFFFF
FFFFFFFF
0006h Total number of uncorrected errors 4 FFFFFFFF

Table of Contents