Log Sense Command
74 T10000: Interface Reference Manual August 2016
001Ah Cooling fan failure Not supported 1
001Bh Power supply failure Not supported 1
001Ch Power consumption Not supported 1
001Dh Drive Maintenance Preventive maintenance of the drive is
required
1
001Eh Hardware A Drive has a hardware fault 1
001Fh Hardware B Hardware not read/write related – not
supported
1
0020h Interface Having problems with the interface, SCSI
parity errors detected
1
0021h Eject Media Eject the media and retry, load failure not
tape snap
1
0022h Download Fail Microcode update failed 1
0023h Drive Humidity Not supported 1
0024h Drive Temperature Temperature inside the tape drive is above
specified range
1
0025h Drive Voltage Not supported 1
0026h Predictive Failure A hardware failure of the drive is predicted 1
0027h Diagnostics Required Dump available 1
0028h
thru
002Eh
Reserved for CSL
002Fh
thru
0031h
Reserved
0032h Lost Statistics Media statistics lost some time in the past. 1
0033h Tape Directory Invalid at Unload The tape directory on the tape cartridge just
unloaded has been corrupted.
1
0034h Tape System Area Write Fail The tape just unloaded could not write its
system area successfully.
1
0035h Tape System Area Read Fail The tape system area could not be read
successfully at load time.
1
0036h No Start of Data The start of data could not be found on tape. 1
0037h Loading failure The operation has failed because the media
could not be loaded and threaded.
1
0038h Unrecoverable Unload failure The operation has failed because the media
could not be unloaded.
1
0039h Automation Interface failure Not supported. 1
TABLE 3-38 TapeAlert Flags (Continued)
Code Flag Name Description
Length
(bytes)