Log Sense Command
August 2016 Commands 79
0402h RBC quality index (see notes) 4 FFFFFFFF
0403h DIA detected error index 4 FFFFFFFF
0404h Reserved 4 FFFFFFFF
0405h Reserved 4 FFFFFFFF
1000h Outer ECC multi symbol correction 48 all FF's
1100h Servo general purpose counter head 0 16 all FF's
1101h Servo general purpose counter head 1 16 all FF's
1200h Servo vote out head 0 32 all FF's
1201h Servo vote out head 1 32 all FF's
1202h Servo no data available head 0 32 all FF's
1203h Servo no data available head 1 32 all FF's
1310h PES histogram head 0 A 128 all FF's
1311h PES histogram head 0 B 128 all FF's
1320h PES histogram head 1 A 128 all FF’s
1321h PES histogram head 1 B 128 all FF’s
1400h Old VR
2
blocks 128 all FF's
1401h Low Viterbi metric 0 128 all FF's
1402h Low Viterbi metric 1 128 all FF's
1403h Low Viterbi metric 2 128 all FF's
1404h Inner ECC correction 128 all FF's
1405h Data valid 128 all FF's
1406h Outer ECC correction 128 all FF's
TABLE 3-40 T10000A and T10000B Vendor Drive Statistics Page Codes (Continued)
Parameter
Code Description
Length
(Bytes)
Default
Threshold
Notes:
• The device write byte count will include file marks and pad bytes. These additional bytes will
not be included in the device read byte count.
• Parameters 0400 – 0402 will not be reset by a Log Select command.