34
1 Press the [MODE key] 5 times to select ‘PRO mode’.
2 Turn the [Jog switch] once toward the ‘’ direction,
to select ‘PRO1 mode’.
3
Press the [Jog switch] to enter the ‘response time change’
state.
The digital display will quickly
blink 3 times to confirm the setting.
5-8. Light Emitting Amount Selection Function
This function allows changing of the light emitting amount. The levels that can be selected will vary depending on
the response time.
Press the MODE
key 5 times.
Turn the Jog switch
once toward
the ‘
’ direction.
Press the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
Press the MODE key
3 times or keep it pressed
for 2 sec. or more.
Press the Jog switch
5 times toward
the ‘’ direction.
4 Turn the [Jog switch] 5 times to enter the ‘light emitting
amount level selection’ state.
5 If the [Jog switch] is pressed, the current ‘light emitting
amount level’ will be displayed.
* FX-301(P), FX-305(P): The factory setting is ‘level 4 (MAX.)’.
FX-301(P)-HS: The factory setting is ‘level 2’.
6
If the [Jog switch] is turned, the current ‘light emitting amount level’ will be displayed.
Set to the desired ‘light emitting amount level’ from ‘light
emitting OFF’ or between ‘level 1’ and ‘level 4’.
*
The levels that can be selected will vary depending on the response time.
•
FX-301(P) FAST, STD, LONG: 4-levels H-SP: 3-levels S-D: 2-levels
•
FX-301(P)-HS FAST, STD, LONG: 4-levels H-SP, S-D: 2-levels
•
FX-305(P) FAST, STD, STDF, LONG, U-LG : 4-levels H-SP: 3-levels
7 If the [Jog switch] is pressed, the digital display will quickly
blink 3 times, confirming the ‘light emitting amount level’
setting.
8 Press the [MODE key] 3 times or keep it pressed for 2 sec.
or more, the amplifier will return to ‘RUN mode’ (normal
sensing operation).
* When the light emitting is set to OFF and the unit returns
to RUN mode (normal sensing operation), ‘ ’ will be
displayed.
Turn the Jog switch to select
the desired light emitting amount level.
Level 4 Level 1Level 2Level 3 0 %
• FX-301(P) FAST, STD, LONG: 4-levels H-SP: 3-levels S-D: 2-levels
• FX-301(P)-HS FAST, STD, LONG: 4-levels H-SP, S-D: 2-levels
• FX-305(P) FAST, STD, STDF, LONG, U-LG: 4-levels H-SP: 3-levels