S-DRIVE - PROGRAMMING PG DRIVES TECHNOLOGY
SK76745/10
PGDT accepts no liability for losses of any kind if the scooter manufacturer does not specify
appropriate safety fence values for a particular scooter application.
2 Speed Parameters
2.1 Forward Acceleration
Adjusts the value for forward acceleration of the scooter, in increments of 1. There are two settings:
Fast This value is used when the slow/fast switch is set to fast.
Slow This value is used when the slow/fast switch is set to slow.
The values are approximately displayed in “units” of 100ms and correspond to the time taken to reach full forward speed from
standstill, i.e. the higher the value the slower the acceleration.
Setting this value too low could cause the scooter to tip when accelerating up a slope.
2.2 Forward Deceleration
Adjusts the value for forward deceleration (or braking) of the scooter, in increments of 1. There are two settings:
Fast This value is used when the slow/fast switch is set to fast.
Slow This value is used when the slow/fast switch is set to slow.
The values are approximately displayed in “units” of 100ms and correspond to the time taken to reach standstill from full forward
speed, i.e. the higher the value the slower the deceleration.
It is the responsibility of the scooter manufacturer to ensure that the emergency stopping
distance is within the distance specified for the country in which the scooter will be used. For
countries requiring CE marking this is as specified in EN12184.
2.3 Reverse Acceleration
Adjusts the value for reverse acceleration of the scooter, in increments of 1. There are two settings:
Fast This value is used when the slow/fast switch is set to fast.
Slow This value is used when the slow/fast switch is set to slow.
The values are approximately displayed in “units” of 100ms and correspond to the time taken to reach full reverse speed from
standstill, i.e. the higher the value the slower the acceleration.
2.4 Reverse Deceleration
Adjusts the value for reverse deceleration (or braking) of the scooter, in increments of 1. There are two settings:
Fast This value is used when the slow/fast switch is set to fast.
Slow This value is used when the slow/fast switch is set to slow.
The values are approximately displayed in “units” of 100ms and correspond to the time taken to reach standstill from full reverse
speed, i.e. the higher the value the slower the deceleration.
It is the responsibility of the scooter manufacturer to ensure that the emergency stopping
distance is within the distance specified for the country in which the scooter will be used. For
countries requiring CE marking this is as specified in EN12184.