Shutting Down the Scalar 1000 4-9
22 June 2004
Shutting Down the Scalar 1000
You can shutdown the Scalar 1000 using the normal
shutdown procedure (recommended for most situations) or
the emergency shutdown procedure.
Except in emergency situations, shutdown the Scalar 1000
using the normal shutdown and not the emergency
shutdown procedure.
Normal Shutdown
Use the following shutdown procedure to shutdown the
Scalar 1000.
If an RMU is installed in the library, wait at least one minute
between powering down the library and powering up the
library. This allows the RMU to properly reset.
Step 1 If necessary, use the button to return to the
Main Menu. The selector defaults to the Mode
selection.
Step 2 Press the button.
Step 3 From the Mode screen, use the button to select
the Shutdown mode.
Step 4 Press the button.
The cursor moves to Shutdown mode and the state
automatically changes to Shutdown. The Accessor
completes the current task, returns to the home position,
and the reboot message appears. See Figure 4-4.
Figure 4-4 Reboot Message
Step 5 Locate the Main Circuit Breaker switch in the lower
right corner at the back of the CM.
See Figure 4-2 on page 4-7 for the location of the
Main Circuit Breaker switch.
Attentio
n
The library may now
be rebooted.

Table of Contents

Other manuals for Quantum Scalar 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar 1000 and is the answer not in the manual?

Quantum Scalar 1000 Specifications

General IconGeneral
BrandQuantum
ModelScalar 1000
CategoryStorage
LanguageEnglish

Related product manuals