UMTS/HSPA Module Series
WCDMA UGxx AT Commands Manual
WCDMA_UGxx_AT_Commands_Manual Confidential / Released 212 / 247
Parameter
This parameter will not be saved.
Example
AT+QAUDCFG="max9860/ulgain",85 //Set uplink gain to 85
OK
12.16. AT+QSIDET Set the Side Tone Gain in Current Mode
AT+QSIDET is used to set the side tone gain value of the current mode.
Write Command
AT+QAUDCFG="max9860/ulgain"[,<level>]
Response
If configuration parameters are omitted:
(+QAUDCFG="max9860/ulgain"),
Return current configuration:
+QAUDCFG: "max9860/ulgain",<level>
OK
If configuration parameters are entered:
OK
ERROR
If error is related to ME functionality:
+CME ERROR: <err>
<Level> Numeric type, indicates the uplink gain of max9860, range: 0-100, default: 80
AT+QSIDET Set the Side Tone Gain in Current Mode
Test Command
AT+QSIDET=?
Response
+QSIDET: (-450~200)
OK