UMTS/HSPA Module Series
WCDMA UGxx AT Commands Manual
WCDMA_UGxx_AT_Commands_Manual Confidential / Released 33 / 247
The flow control is applied for data mode.
Example
AT+IFC=2,2 //Open the hardware flow control
OK
AT+IFC?
+IFC: 2,2
OK
3.4. AT+IPR Set TE-TA Fixed Local Rate
AT+IPR is used to query and set the baud rate of the UART. The default baud rate value (<rate>) is 0bps.
<rate> setting will not be restorable with AT&F.
0 None
2 CTS flow control
AT+IPR Set TE-TA Fixed Local Rate
Test Command
AT+IPR=?
Response
+IPR: (list of supported auto detectable <rate>s),(list of
supported fixed-only<rate>s)
OK
Read Command
AT+IPR?
Response
+IPR: <rate>
OK
Write Command
AT+IPR=<rate>
Response
This parameter setting determines the data rate of the TA on
the serial interface. After the delivery of any result code
associated with the current command line, the rate of
command takes effect.
OK
Maximum Response Time
300ms
Reference
V.25ter
NOTE
Quectel
Confidential

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel UG Series and is the answer not in the manual?

Quectel UG Series Specifications

General IconGeneral
BrandQuectel
ModelUG Series
CategoryControl Unit
LanguageEnglish

Related product manuals