UMTS/HSPA Module Series
WCDMA UGxx AT Commands Manual
WCDMA_UGxx_AT_Commands_Manual Confidential / Released 23 / 247
Table 3: ATV0&ATV1 Result Codes Numeric Equivalents and Brief Description
2.17. ATE Set Command Echo Mode
ATE controls whether the module echoes characters received from TE during AT command state.
Parameter
ATV1
ATV0
Description
OK
0
Acknowledges execution of a command
CONNECT
1
A connection has been established; the DCE is moving from
command state to online data state
RING
2
The DCE has detected an incoming call signal from network
NO CARRIER
3
The connection has been terminated or the attempt to
establish a connection failed
ERROR
4
Command not recognized, command line maximum length
exceeded, parameter value invalid, or other problem with
processing the command line
NO DIALTONE
6
No dial tone detected
BUSY
7
Engaged (busy) signal detected
NO ANSWER
8
"@" (Wait for Quiet Answer) dial modifier was used, but
remote ringing followed by five seconds of silence was not
detected before expiration of the connection timer (S7)
ATE Set Command Echo Mode
Execution Command
ATE<value>
Response
This setting determines whether or not the TA echoes
characters received from TE during command state.
OK
Maximum Response Time
300ms
Reference
V.25ter
<value> 0 Echo mode off
1 Echo mode on
Quectel
Confidential

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel UG Series and is the answer not in the manual?

Quectel UG Series Specifications

General IconGeneral
BrandQuectel
ModelUG Series
CategoryControl Unit
LanguageEnglish

Related product manuals